Selecting a ZM power supply depends on the load voltage, required current, need for battery backup and installation method. The ZM product family includes AC/DC power supplies, modules for parallel operation, floating-operation power supplies, compact DC power systems, high-power systems and DC/DC converters. This guide outlines the information needed before selecting a unit and explains the differences between the main variants.

What data to define before selecting a ZM power supply

Selection should begin with the requirements of the loads and the installation. Rated power alone is not sufficient, as the power supply must deliver the required current across the entire operating voltage range and, in a floating-operation system, supply the loads and charge the battery at the same time.

  • Output voltage: Determine the nominal voltage of the loads and the permissible voltage range at their terminals.
  • Load current: Add up the current requirements of all loads, taking into account their operating states, starting currents and any planned system expansion.
  • Battery backup: Determine whether the loads must continue operating after the primary power source fails and, if so, for how long.
  • Batteries: Specify the battery type, voltage, capacity, connection arrangement and requirements for charging and disconnection in the event of deep discharge.
  • Redundancy: Determine whether the power supply must remain available if one module fails. The number of modules should be selected to ensure that the required load can still be supplied after a failure.
  • Signalling and communication: Specify which status conditions must be indicated locally, via relay contacts or through a communication interface.
  • Installation and industry-specific requirements: Check the available space, mounting method, environmental conditions and applicable standards for the intended application.

When calculating a floating-operation system, the load current must be considered separately from the battery charging current. The power supply’s current limits, voltage drops in the cables and battery operating conditions must also be taken into account. Battery capacity and backup time require separate calculations based on the assumed load profile.

When is a single ZM modular power supply sufficient

If an application requires a single regulated DC voltage and does not need parallel operation or battery backup, a standard ZM modular power supply may be suitable. The product family includes 12 V, 24 V and 48 V variants with different output current ratings. Versions are available for chassis mounting, DIN rail mounting or Eurocard subrack installation. The mounting method and connections depend on the specific model.

Before selecting a model, consider the input voltage range, current limiting characteristics, permissible cooling conditions and signalling options. These parameters must match the operating requirements of the loads. Nominal voltage and current ratings alone are not sufficient.

When to use ZM-R and a redundant configuration

ZM-R modules enable parallel operation with equal current sharing between the connected power supplies. They can be combined to increase the available output current or to build a redundant system. Up to 15 modules can be connected in parallel, subject to the configuration requirements.

Connecting several power supplies in parallel does not, by itself, provide redundancy. In a redundant configuration, the remaining modules must continue to supply the full required load if one module is disconnected. The design must therefore account for the load current, the permissible load on each module, the protection arrangements and system behaviour during a failure or maintenance.

How to select a ZM floating-operation power supply for a battery

ZM-B, ZM-A, ZM-AZ and ZM-AZC floating-operation power supplies are designed to work with batteries. When the primary power source is available, they supply the loads and charge the battery. If the primary source fails, the battery takes over the power supply. The functionality varies between power supply models, so the series designation must be matched to the installation requirements.

ZM-B and ZM-A power supplies operate in floating mode. They provide charging current adjustment, temperature compensation, and optical and relay indication of operating status. The ZM-AZ measures the resistance of the battery circuit. An increase may indicate battery deterioration and higher internal resistance, but it may also point to deteriorating connections or a problem in the battery circuit. However, this measurement does not replace capacity calculations or checks of the battery as a whole. The ZM-AZC provides digital communication, using an RS-232 or RS-485 interface, depending on the model.

When selecting a floating-operation power supply, check that its maximum output current can cover both the load demand and the required battery charging current at the same time. Also verify the charging voltage required for the selected battery, temperature compensation, the alarms provided and the method of disconnecting the battery in the event of excessive discharge.

Power supplies for fire protection systems

In fire protection systems, power supply selection depends on more than just voltage and current. A version intended for the specific installation must be selected, taking into account the requirements for the complete device and its installation. The scope of certification depends on the specific model.

CNBOP-PIB certification and compliance with EN 54-4 and EN 12101-10 apply to selected 24 V versions from the ZM-PZ, ZM-AZ and ZM-AZC ranges. The selected model must be listed in the relevant certificate and used in accordance with the specified conditions. Requirements for the complete solution also cover the enclosure, batteries and mounting method.

When to choose ZM-PS, ZM-DC or ZM-UPS

If a single module cannot provide the required current, a 19-inch rack-mounted power supply system with ZM-R modules operating in parallel can be used. The ZM-PS5-24V120A model consists of five 24 V / 24 A modules and provides a maximum output current of 120 A. The system can provide power supply module redundancy. The number of modules must be selected so that, if one module fails, the remaining modules can continue to supply the required loads.

The ZM-UPS compact DC power system combines a floating-operation power supply and batteries in a 3U Eurocard subrack designed for installation in a 19-inch rack cabinet. The range includes variants with different output voltages and current ratings, and accommodates up to four 12 V / 12 Ah batteries internally. ZM-UPS provides local DC power with battery backup in a limited rack space. The backup time must be selected based on the actual load and battery configuration.

ZM-DC converters can be powered from two independent sources. By default, these are 220 V DC sources, but the converters can also be powered from a 230 V AC mains supply or from both a 220 V DC source and a 230 V AC source simultaneously. When selecting a converter, consider the input and output voltages, current range and the required dual-source power supply arrangement, where specified by the system design.

ZM 110/220 V power supplies are designed for installations using 110 V DC or 220 V DC. Depending on the model, the input may be 230 V AC or 220 V DC, while the output voltage is either 110 V DC or 220 V DC. The selected version must match the installation’s input voltage and required output voltage.

Floating operation power supply in a wall-mounted enclosure

When battery-backed power is required in a compact wall-mounted enclosure, the ZMS guaranteed power supply stations are worth considering. They combine a ZM modular power supply with VRLA AGM batteries in a lockable enclosure rated IP42.

They are designed to supply loads with guaranteed voltages of 12 V, 24 V or 48 V, at power levels of up to 300 W. Depending on the enclosure size, battery capacities of up to 80 Ah for 12 V systems, 40 Ah for 24 V systems or 18 Ah for 48 V systems can be accommodated.

The stations provide uninterrupted transfer to battery power, protection against deep battery discharge and relay-based indication of a general alarm. Thanks to their integrated design, ZMS units simplify installation and reduce the space required in control cabinets.

This solution is intended for industrial and railway installations, as well as security systems where continuity of power supply and easy monitoring of device status are important.

Comparison of the main ZM family variants

Variant Function When to consider it
ZM AC/DC modular power supply Powering a single load or a group of loads without battery backup
ZM-R Power supply with parallel operation capability Increasing the output current or implementing redundancy
ZM-B / ZM-A Floating-operation power supply with battery backup Backup power for loads; charging and signalling functions depend on the model.
ZM-AZ / ZM-AZC Floating-operation power supply with diagnostics Battery circuit resistance monitoring; ZM-AZC additionally provides digital communication
ZM-PZ Certified 24 V floating-operation power supply versions Fire protection applications, subject to verification of the model and documentation
ZM-PS High-power system built from ZM-R modules Higher output current and the option of redundant configuration
ZM-UPS Compact DC power system in a 3U Eurocard subrack Local floating-operation power supply with batteries in a 19-inch rack cabinet
ZMS Integrated guaranteed power supply station with batteries in a wall-mounted enclosure When compact 12 V, 24 V or 48 V floating-operation power supply up to 300 W is required, without having to install the power supply and batteries in the main control cabinet
ZM-DC / ZM 110/220 V DC voltage conversion or supply DC-powered installations requiring a different voltage level or a specific input configuration

How to prepare the data for selection

A technical inquiry should include a power supply diagram or a brief list of requirements: input voltage, required output voltage and current, load type, backup time, battery type and capacity, required signalling method, communication interface, installation conditions and applicable standards. For redundant systems, specify whether the system must continue to supply the full load following the failure of one module or whether reduced power is acceptable.

This information makes it possible to identify the appropriate ZM variant and confirm that its specifications meet the application’s requirements. Details of the circuit design, electrical parameters, backup requirements and diagnostic functions can be submitted to MERAWEX. This will help determine the appropriate model and configuration before implementation.

Other technical articles

  • How to plan a power supply system replacement without risking continuity of operation?

    08/09/2026

    Key principles for replacing a power supply system in an operational facility

  • Uninterruptible Power Supply for Telecommunications and Remote Control Systems – How to Design a System for Power Outages

    25/08/2026

    Selecting floating-operation power supplies for telecommunications and telecontrol systems – key principles of system design, battery backup and monitoring

  • Guaranteed 24 V DC power supply in the power industry – how to ensure continuity of substation automation and telecontrol systems?

    03/09/2026

    Key principles for selecting DC power systems, battery backup, diagnostics and redundancy for substation automation and telecontrol systems

  • Select a ZM power supply for your application

    Are you selecting a power supply for a new installation or upgrading an existing power supply system? Send us your required voltage and current, battery backup requirements and installation conditions. Our engineers will help you select the right ZM variant, taking into account the technical requirements, diagnostics and continuity of power supply.

    • 1

      After receiving your enquiry, we will contact you by phone or email.

    • 2

      During the call, we will discuss your requirements and propose suitable solutions.

    • 3

      If necessary, we will arrange additional technical consultations.

    • 4

      We approach each case individually, so you can be sure that our response will be tailored to your requirements.